Internal pressure column ultrafiltration
Ningbo Rixin Hengli Technology is a company
under the "National Thousand Talents Program"
High tech enterprises established by specially appointed experts
Specifications | A | B | C | D | L1 | L2 |
RTL-4046-PAN | 167 | 115 | 110 | 90 | 1163 | 963 |
Component parameters | Component model | RTL-4046-PAN |
Effective membrane area (m²) | 4 | |
Shell material | UPVC | |
Casting form | Epoxy Resin | |
Inlet/outlet interface | Φ32-UPVC | |
Sealing form and material | O-ring/EPDM | |
Equipment weight (net weight/gross weight, kg) | 4.4/4.8 | |
APPLICATION PARAMETERS | Filtration flux(25ºC) | 40-120 L/m²/hr |
Flow range | 0.16-0.48 m³/hr | |
Backwash flux | 100-120 L/m²/hr | |
PH range during operation | 3-9 | |
Temperature | 1-40ºC | |
Maximum inlet component pressure (at 20ºC) | 3 bar | |
Maximum transmembrane pressure difference during operation | 2 bar | |
Maximum backwash pressure | 2 bar | |
Flow direction setting | Internal pressure structure, cross flow/dead end filtration | |
Expected turbidity of produced water | ≤ 0.5 NTU | |
Expected Water Production Sludge Density Index (SDI) | ≤ 2.5 |
Suggested parameters for application design | Type of inflow | Tap-water | Groundwater | Surface Water | Recycled Water | Waste Water | |||
Turbidity | <1 | <2 | <2 | <5 | <15 | <50 | <20 | <20 | |
Security filtration | Optional | Recommend | |||||||
Design flux (L/m²/hr) |
90-100 | 80-90 | 70-80 | 70-80 | 60-70 | 50-60 | 50-70 | 20-40 | |
Rate of recovery | 95% | 90% | 85% | 80% | 70% | ||||
Backwash interval | 60m | 30m | 20m | ||||||
Backwash time | 60s | 60s | 60s | 60s | 60s | 100s | 100s | 100s | |
Backwash pressure | 0.15MPa-0.2Mpa | ||||||||
Backwash flux (L/m²/hr) |
150-200 | 100-150 | 60-100 | ||||||
Chemical Cleaning | Not recommended | Optional | Recommend |