Municipal sewage

RO system operation data
A system B system
Water inlet pressure 12.03bar Water inlet pressure 12.75bar
Concentrated water pressure 11.02bar Concentrated water pressure 12.01bar
Water production flow rate 58m³/h Water production flow rate 65m³/h
Concentrated water flow 56m³/h Concentrated water flow 64m³/h
Rate of recovery 50.87% Rate of recovery 50.38%
Inlet conductivity 5565us/cm Inlet conductivity 5698us/cm
Water conductivity 29us/cm Water conductivity 33us/cm
Desalination rate 99.47% Desalination rate 99.42%
Inlet water temperature 10-25℃ Inlet water temperature 10-25℃

Technological Process:
(1)Sedimentation tank → PH adjustment tank → filter cloth filter → intermediate water tank → UF security filter → UF system → UF production water tank → RO security filter → RO system → clean water tank → workshop usage point
System Overview:
UF system: 54 units per set, with a total of 324 units in 6 sets.
RO system: 90 units per set, with a total of 720 units in 8 sets. The designed water production per set is greater than 50m ³/h, and the system recovery rate is greater than 50%. RTL-FR-8040 is used.
Technical Services:
On site guidance for installation, debugging, and technical training.

Customer evaluation: RTL product system has high desalination rate, low pressure drop, and stable anti pollution performance.