Convention Curtain ultrafiltration series
Ningbo Rixin Hengli Technology is a company
under the "National Thousand Talents Program"
High tech enterprises established by specially appointed experts
RTL-L series curtain type ultrafiltration membrane module model parameters and basic indicators | ||||
Membrane module model | RTL-15L-PVDF | RTL-20L-PVDF | RTL-30L-PVDF | RTL-30Ls-PVDF (For MCR environment use only) |
External dimensions (L1×L2×D) | 1020×720×48 mm | 1520×720×48 mm | 2020×720×48 mm | 1520×720×48 mm |
Integrated membrane stack size (width x height) | 1600×1500 mm | 1600×2000 mm | 1600×2500 mm | 1600×2000 mm |
Membrane Area | 15 m² | 20 m² | 30 m² | 30 m² |
Hollow fiber membrane type | PVDF (Hook woven pipe type) | |||
Fiber inner/outer diameter | 1.0/2.1 mm | |||
Membrane Pore Size | 0.03μm |
Basic parameters and application methods of RTL curtain ultrafiltration membrane components | ||
Basic parameters | Membrane | Polyvinylidene fluoride (PVDF) |
Fiber bonding material | Epoxy resin+polyurethane | |
Material of water collection pipe | ABS pipe | |
Filter effects | Suspended solids>1 μ m | 100% |
Microorganism | 99.99% | |
Turbidity of produced water | ≤ 1 NTU | |
Water production SS | ≤ 5 mg/L | |
Conditions of Use | Filtering method | Negative pressure suction, from outside to inside |
Working pressure | 0~-0.05 MPa | |
Operation temperature | 10~35℃ | |
PH range during use | 6~9(pH range 2-12 during cleaning) | |
Mineral oil content in raw water | <3 mg/L | |
Maximum residual chlorine concentration in the inlet water | 200 mg/L(Maximum residual chlorine concentration during cleaning 3000mg/L) | |
Aeration intensity (Nm3/m2 · h membrane stack projection area) | 40~80 | |
Design water production flux | 8~25 L/m²·h | |
Design backwash flux | 16~50 L/m²·h | |
Operation mode | Total daily working hours | 19.2-22 h |
Work cycle | Production time is 8-28 minutes, stop for 2 minutes | |
Maximum transmembrane pressure difference | 0.05 MPa | |
Maximum backwash pressure | 0.1 MPa |